Project Description
Hybrid Inverter 3000W 3kVA 5000W 5kVA
Models
HF4830S60
HF4840S60
HF4850S80
Rated input voltage
220/230Vac
Input voltage range
(170Vac~280Vac) ±2%(90Vac-280Vac) ±2%
Frequency
50Hz/ 60Hz (Auto detection)
Overload/short circuit protection
Circuit breaker
Efficiency
>95%
Conversion time (bypass and inverter)
10ms (typical)
AC reverse protection
Available
Maximum bypass overloadcurrent
40A
Inverter mode
Output voltage waveform
Pure sine wave
Rated output power (W)
3000
4000
5000
Power factor
1
Rated output voltage (Vac)
230Vac
Output frequency
50hz/60hz
Peak power
6000VA
8000VA
10000VA
Loaded motor capability
2HP
3HP
4HP
Output short circuit protection
Circuit breaker
Bypass breaker specifications
40A
Rated battery input voltage
48V (Minimum starting voltage 44V)
Mains charging
Battery type
Lead acid or lithium battery
Maximum charge current
60A
Charge voltage range
40 -58Vdc
Short circuit protection
Circuit breaker and blown fuse
Circuit breaker specifications
40A
Overcharge protection
Alarm and turn off charging after 1 minute
PV charging
Maximum PV open circuit voltage
145Vdc
PV operating voltage range
60-145Vdc
MPPT voltage range
60-115Vdc
Battery voltage range
40-60Vdc
Maximum output power
3200W
4200W
PV charging current range(can be set)
0-60A
0-80A
Charging short circuit protection
Blown fuse
Wiring protection
Reverse polarity protection
Certified specifications
Certification
CE(EN62040-1)
EMC certification level
EN62040-2, C2
Operating temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Heat dissipation
Forced air cooling, variable speed of fan
Communication interface
USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control
Size (L*W*D)
430mm*338mm*126mm
Weight (kg)
10
Models | HF4830S60 | HF4840S60 | HF4850S80 |
Rated input voltage | 220/230Vac | ||
Input voltage range | (170Vac~280Vac) ±2%(90Vac-280Vac) ±2% | ||
Frequency | 50Hz/ 60Hz (Auto detection) | ||
Overload/short circuit protection | Circuit breaker | ||
Efficiency | >95% | ||
Conversion time (bypass and inverter) | 10ms (typical) | ||
AC reverse protection | Available | ||
Maximum bypass overloadcurrent | 40A | ||
Inverter mode | |||
Output voltage waveform | Pure sine wave | ||
Rated output power (W) | 3000 | 4000 | 5000 |
Power factor | 1 | ||
Rated output voltage (Vac) | 230Vac | ||
Output frequency | 50hz/60hz | ||
Peak power | 6000VA | 8000VA | 10000VA |
Loaded motor capability | 2HP | 3HP | 4HP |
Output short circuit protection | Circuit breaker | ||
Bypass breaker specifications | 40A | ||
Rated battery input voltage | 48V (Minimum starting voltage 44V) | ||
Mains charging | |||
Battery type | Lead acid or lithium battery | ||
Maximum charge current | 60A | ||
Charge voltage range | 40 -58Vdc | ||
Short circuit protection | Circuit breaker and blown fuse | ||
Circuit breaker specifications | 40A | ||
Overcharge protection | Alarm and turn off charging after 1 minute | ||
PV charging | |||
Maximum PV open circuit voltage | 145Vdc | ||
PV operating voltage range | 60-145Vdc | ||
MPPT voltage range | 60-115Vdc | ||
Battery voltage range | 40-60Vdc | ||
Maximum output power | 3200W | 4200W | |
PV charging current range(can be set) | 0-60A | 0-80A | |
Charging short circuit protection | Blown fuse | ||
Wiring protection | Reverse polarity protection | ||
Certified specifications | |||
Certification | CE(EN62040-1) | ||
EMC certification level | EN62040-2, C2 | ||
Operating temperature range | -15°C to 55°C | ||
Storage temperature range | -25°C ~ 60°C | ||
Humidity range | 5% to 95% (Conformal coating protection) | ||
Noise | ≤60dB | ||
Heat dissipation | Forced air cooling, variable speed of fan | ||
Communication interface | USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control | ||
Size (L*W*D) | 430mm*338mm*126mm | ||
Weight (kg) | 10 |
Operating Temperature-25 ~ +60 ºCTransformerHigh Frequency-TransformerProtection ClassIP20CoolingFanMax. Altitude2000 mInterfaceRS 485, USBDisplayLCD, LEDProtection Features Protection FeaturesShort Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection
Why choose the hybrid inverter controller instead of solar controller and inverter ?
Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sine wave. Two output modes: mains bypass and inverter output; uninterrupted power supply.
Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging.
Advanced MPPT technology with an efficiency of 99.9%.
Designed with a LCD screen and 3 LED indicators for dynamic display of system data and operating status.
ON/OFF rocker switch for AC output control.
Power saving mode available to reduce no-load loss.
Intelligent variable speed fan to efficiently dissipate heat and extend system life.
Lithium battery activation design, allowing access of lead-acid battery and lithium battery.
360 ° all-round protection with a number of protection functions.
Complete protections, including short circuit protection, over voltage and under voltage protection, overload protection, reverse protection, etc
The importance of hybrid inverter controller
HF series is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage & means charging energy storage and AC sine wave output The DC-AC inverter module employs advanced SPWM technology and outputs pure sine wave to convert DC into AC. It is ideal for AC loads such as household appliances, power tools, industrial equipment, and electronic audio and video equipment Comprehensive electronic protections keep the entire system safer and more stable.